SH131 Portable Octane & Cetane No. Tester ASTM Dual Fuel 20s Fast Test

SH131 Portable Octane & Cetane No. Tester ASTM Dual Fuel 20s Fast Test

Brand Name: Shengtai Instrument
Model Number: SH131
MOQ: 1
Payment Terms: T/T
Supply Ability: 3000 sets/year
Detail Information
Place of Origin:
China
Certification:
ASTM D2699-86 ASTM D2700-86 ASTM D4737-03 ASTM D613 EN ISO 5165
The Measurement Range Of Octane Number:
40-120
The Measurement Range Of Cetane Number:
20-100
Measurement Time:
<20s
Host:
224*106*40mm(L*W*H)
Sensors:
60*100mm
Weight:
5KG
Packaging Details:
carton
Highlight:

Portable Octane Cetane Tester

,

ASTM Dual Fuel Tester

,

20s Fast Octane Cetane Test

Product Description

SH131 Octane number cetane number tester

SH131 octane cetane number tester is adopt international advanced measuring principle, according to the diversity of domestic oil product design and development, fill the blank of the variety of product testing, with precise and can quickly detect the octane value of the product and cetane number, both Chinese and English two languages, the large capacity data storage and can print directly measured values, page design humanized operation is simple, adopts imported case and chips, sensors use alloy metal seal design, super long standby, a charging circuit suitable for on-site, field and laboratory work.

Main features

  • Can simultaneously detect gasoline octane number and diesel cetane number, one machine dual use.
  • Through long-term data acquisition instrument, database, complete with new technology to develop a variety of detection mode, detectable methanol gasoline, ethanol gasoline, naphtha, solvent oil, straight run oil, light oil, aromatic hydrocarbons, MTBE, manganese base, methanol diesel, catalytic diesel oil, biological diesel oil, emulsified diesel oil and other oil products, fill the some product octane number and cetane number blank.
  • The introduction of international dielectric constant measurement principle, according to the Chinese market demand design and development, is a completely in line with the domestic market, and includes the advantages of the original domestic testing instruments.
  • Fast and accurate detection, simple operation, large screen Chinese display, EL backlight support, easy to use in dim light environment, host panel Chinese menu operation.
  • Germany imported original instrument shell, durable, and small and easy to carry, the chip and core components are imported, increase the sensitivity and service life of the instrument, the circuit board can be guaranteed for three years, the company promises that any non-human quality problems within three years, free replacement.
  • Sensor alloy metal fully sealed manufacturing, packing box has high strength, high impact resistance, absolutely sealed waterproof, moistureproof, dustproof, with square sponge inside.
  • The upper and lower limits of the mode can be set in advance, which can be automatically displayed beyond the range to facilitate user detection.
  • With automatic shutdown energy saving function, low power consumption design, 4 rechargeable batteries, can be recycled charging, battery reliability is stronger.

Measuring principle

Octane number meter is the principle of the octane number of gasoline and diesel cetane number of insulation permeability and electromagnetic induction measurement of charge characteristics.The results are determined by measuring the dielectric properties of the oil product against a known data model that is stored in memory.

The induction device is very precise and can measure small changes in dielectric parameters.Thus, the octane number and cetane number of petroleum products can be detected.

Technical parameters

Measurement items: vehicle gasoline and diesel oil

Octane number measurement according to: ASTM D2699-86, ASTM D2700-86.

Cetane number of diesel oil is measured according to ASTM D4737-03, ASTM D613, EN ISO 5165.

Operating range: temperature -10℃~+40℃, relative humidity 30%~81%R.H., atmospheric pressure 64~ 106Kpa

Specification

Parameters to describe Numerical
Octane number measurement range (ON) ON as a unit of measurement (can be adjusted according to customer requirements) 40-120
Allowable measurement error of octane meter, per unit (maximum) ±0.5(Contrast that with the desktop standard method)
The range within which an octane meter can be measured, per unit (maximum) ±0.2
Cetane number measurement range (CN), in CN units (can be adjusted according to customer requirements) 20-100
Allowable measurement error of cetane number meter, CN (Max) ±1(Contrast that with the desktop standard method)

The floating range of the results of a cetane number meter, in CN units (maximum)

Measuring time (seconds)

 

±0.5

Measuring time (seconds) <20
The critical value of low battery voltage V 2.5
Host machine, mm(length × width × height) 224x106x40
Sensor, mm 60х100
Weight, Kg(maximum) 5
Duration of service (in hours) 15
Output way LCD display, print out
Current consumption 30ma

 

SH131 Portable Octane & Cetane No. Tester ASTM Dual Fuel 20s Fast Test

 

Packing list

S/N Name Quantity Unit Remarks
1 Host 1 set  
2 Sample cup 1 piece  
3 Power cord 1 piece  
4 Instruction 1 copy  
5 Packing list 1 copy  
6 Certificate warranty card 1 copy