products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Viscosity Tester
Created with Pixso.

Transformer Oil Testing Equipment SH112 Automatic Calculation For Kinematic Viscometer

Transformer Oil Testing Equipment SH112 Automatic Calculation For Kinematic Viscometer

Brand Name: Shengtai Instrument
Model Number: SH112
MOQ: 1
Payment Terms: T/T
Supply Ability: 100 set per month
Detail Information
Place of Origin:
China
Performance Standards:
GB265-88,,ASTM D445
Determination And Cleaning:
Visual Observation, Manual Cleaning And Automatic Timing
Temperature Control Range:
Room Temperature-100℃
Decision Procedure:
Visual Observation, Automatic Calculation
Temperature Control Accuracy:
±0.1℃
Printer:
Thermal Printer, High-speed And Lower Consumption, With 55 Millimeter-wide Printing Paper
Temperature Testing Components:
Precise Imported Platinum Electric Resistance
Heating Power:
1800W
Sample Installing Quantities:
2pieces
Working Environment:
Temperature: 0℃~40℃ Relative Humidity: <80%
Power Supply:
AC220V±10% 50Hz
Dimension(largest):
360*370*520(L*W*H)
Weight:
20Kg
Packaging Details:
wooden case
Highlight:

Transformer oil kinematic viscometer

,

Automatic kinematic viscosity tester

,

SH112 viscosity testing equipment

Product Description

SH112 Transformer Oil Kinematic Viscometer

The SH112 Petroleum Kinematic Viscosity Tester complies with GB/T265, Method for the Determination of Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity.
It can also serve as a high-viscosity constant-temperature water bath for other tests.
Temperature is measured by a high-precision PT100 platinum resistance sensor, with an adjustable range from ambient temperature up to 100℃.
Viscosity results are calculated automatically. This instrument also meets ASTM D445 requirements.

Technical data

Performance StandardsGB265-88,,ASTM D445
Determination and cleaningVisual observation, manual cleaning and automatic timing
Temperature Control RangeRoom temperature-100℃
decision procedureVisual observation, automatic calculation
Temperature Control Accuracy±0.1℃
PrinterThermal printer, high-speed and lower consumption, with 55 millimeter-wide printing paper
Temperature Testing ComponentsPrecise imported platinum electric resistance
Heating power1800W
Sample Installing Quantities2pieces
Working EnvironmentTemperature: 0℃~40℃ Relative Humidity: <80%
Power SupplyAC220V±10% 50Hz
Dimension(largest)360*370*520(L*W*H)
Weight20Kg
Performance StandardsGB265-88,,ASTM D445
Capillary ViscometerConform to SH/T0173-92 Technical Conditions of Glass Capillary Viscometer, Conform to JJG155 Verification Regulation of Routine Capillary Viscometer
Method of Display7 inch color LCD
Temperature Control RangeRoom temperature-100℃
Testing RangeKinematic Viscosity:0.5~20000mm2/s
Temperature Control Accuracy±0.1℃
Timing Accuracy±0.1S
Timing Range0.1S-999.9S
Homoeothermic Bathtub300×300mm double layer
PrinterThermal printer, high-speed and lower consumption, with 55 millimeter-wide printing paper
Temperature Testing ComponentsPrecise imported platinum electric resistance
Heating power800W
Sample Installing Quantities4 pieces
Working EnvironmentTemperature: 0℃~40℃ Relative Humidity: <80%
Power SupplyAC220V±10% 50Hz ±5%
Dimension(largest)360*370*520(L*W*H)
Weight15Kg

 

Transformer Oil Testing Equipment SH112 Automatic Calculation For Kinematic Viscometer

 

The main features are as follows:

1.The constant temperature bath is a round glass tank with even temperature distribution in the bath and good temperature control effect

2,the instrument adopts precision digital temperature controller to control the temperature in the bathtub, the executive components are solid-state relay SSR, with temperature control accuracy and accuracy, no contact, no noise, no spark, fast action, long life and other characteristics.

3, Capillary card adopts three point vertical type, flexible and convenient operation, reliable clamping.

4, the viscosity tube can be selected according to the needs of the viscosity tube or wusoll viscosity tube.

5. With U disk input function, data can be output to PC for long-term storage.

Technical parameters:

Display mode: digital display;

Stopwatch timing: 0.05 seconds --99 minutes 99.99 seconds;

Ambient temperature: 5℃-40℃;

Ambient humidity: < 85%;

 

Customer supplied supplies are required: water or glycerin.

Strictly according to national standards, the viscosity tube test before the need to clean the following reagents: solvent oil or petroleum .

 

Petroleum kinematic viscometer for turbine oil the standard ASTM D445 GB/T265 turbine oil viscosity tester

 

ASTM D445 Petroleum Products Kinematic Viscosity Tester Digital Viscometer

 

Packing list

 

S/NNameQuantityUnitRemarks
1host1set 
2Special thickened sealed glass cylinder1piece1
3Water bath top cover assembly1setContains 4 capillary stands
4Control cable1piece 
5Fuse tube1piece10A
6Capillary viscometer4pieceCan choose
7Operating instruction1copy 
8Wash ears ball1piece 
9Packing list1copy 
10Certificate of approval1copy