products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Pharmaceutical Testing Instruments
Created with Pixso.

7-inch LCD Rapid and Quantitative Detection of Mycotoxins with ST2000A Pharmaceutical Testing Instruments

7-inch LCD Rapid and Quantitative Detection of Mycotoxins with ST2000A Pharmaceutical Testing Instruments

Brand Name: Shengtai Instrument
Model Number: ST-2000A
MOQ: 1 carton
Payment Terms: T/T
Supply Ability: 10 cartons per week
Detail Information
Place of Origin:
China
Vomiting Toxin::
0.01-5,000 Ug/kg
Aflatoxin::
0.01-50ug/kg
Corn Eryenone::
0.01-1000ug/kg
Highlight:

pharmaceutical testing hardness tester in pharma

Product Description

7-inch LCD Rapid and Quantitative Detection of Mycotoxins with ST2000A Pharmaceutical Testing Instruments

 

 

 

 

7-inch LCD Rapid and Quantitative Detection of Mycotoxins with ST2000A Pharmaceutical Testing Instruments 0

 

 

ST2000A Mycotoxin tester can be rapid and quantitative detection of aflatoxin, T2 toxin, vomiting toxin, ochretoxin, voloma toxin, corn eryenone in food, feed, grains, cooking oil, condiments and other foods.

The mycotoxin detector applies the principle of time-resolved fluorescence competition to inhibit immunotomography, which contains the mycotoxin residue in the sample, it will react with the specific monoclonal antibody of the fluorescence microsphere markers, inhibiting the binding of the antibody and the NC membrane in detecting the linear coupling object. If the mycotoxin residue content in the sample is high, the antibody volume on the detection line will be reduced, and the fluorescence intensity of the detection line becomes weakened.

Performance characteristics:

1.7-inch LCD touch screen Chinese display, humanized operation interface, accurate and intuitive reading.

2. The instrument has data storage function, and the interface design adopts USB, RS232 to facilitate data storage and related processing.

3.. Automatically save the test results, large data storage, and built-in micro printer that can print the test results in real time.

Technical parameters:

1. Center wavelength of the excitation spectrum: 365nm

2. Center wavelength of the receiving spectrum: 610nm

3. Test scope:(Choose different test cards and reagents)

Vomiting toxin: 0.01-5,000 ug/kg

aflatoxin: 0.01-50ug/kg

Corn eryenone: 0.01-1000ug/kg

Oretoxin: 0.01-500ug/kg

T2 toxin: 0.01-5000ug/kg

Voloma toxin: 0.01-5000ug/kg

4. Accuracy: CV value: ≤ 3%

5. Absorption repeatability: ± 0.005