Brand Name: | Shengtai Instrument |
Model Number: | SH112C |
MOQ: | 1 |
Payment Terms: | T/T |
Supply Ability: | 100000sets/year |
SH112C Automatic Kinematic Viscometer Equipped With 2 Sets Of Capillary Viscometers
SH112C automatic kinematic viscometer is designed and manufactured in strict accordance with GB / T265 and astmd445 standards. It can measure the kinematic viscosity of transparent and opaque liquids to the same accuracy, including crude oil, light fuel oil, lubricating oil, additives and silicone oil. It is also suitable for measuring the kinematic viscosity of samples with high wax content or samples containing insoluble components at room temperature. Fully automatic constant temperature, viscosity test, cleaning and drying viscometer do not need random operation. After setting out, the operator can leave the site, and the instrument can complete all tasks automatically.
ASTM D445 Automatic Kinematic Viscometer with Glass Capillary
ASTM D445 ISO3104 Transformer Oil Diesel Fuel Oil Kinematic Viscosity Tester
Automatic Viscometer for Testing Kinematic Viscosity of Oil
ASTM D445 Lab Fully Automatic Transformer Oil Kinematic Viscometer Price
ASTM D445 Laboratory Petroleum Products Capillary Automatic Kinematic Viscometer Price
Automatic ASTM D445 Kinematic Viscometer for Fuel Oils
Kinematic Viscosity Tester ASTM D445 Automatic Viscometer astm d445 Viscosity Tester astm d445 Viscosity Apparatus
ASTM D445 Kinematic Viscosity Tester for gear oil hydraulic oil turbine oil
The working principle is to put the sample into the selected capillary viscometer, the capillary immersed in a constant temperature bath. The sample is inhaled to the calibration position. When the sample flows to the upper calibration position, the instrument starts to record the time. When the sample flows to the calibration position, the recording time stops. The instrument will automatically calculate the kinematic viscosity of the sample.
The main features
1. Large size color touch screen, resolution up to 1024*600.
2. Adopt 32-bit microprocessor as the control core, independently developed graphical man-machine interface for operation.
3. The main parts and electronic components of the instrument are imported devices with good stability.
4. The instrument has automatic timing function, automatic calculation, automatic printing, automatic cleaning, automatic drying and other functions.
5. Double cylinder body, fast and stable temperature control, heating rate >
5 ℃ / min.
6. Equipped with LED soft light, uniform filling light, easy to observe.
7. With viscometer parameter storage function.
8. After upgrade, 199 groups of historical data can be stored for easy query;
At the same time can output U disk function
★9. with date password setting function. (optional)
10. standard micro printer automatic measurement automatic thermal printing
★11.with TCP network transmission function (optional)
★12. can be uploaded and connected to LIMIS system (optional)
Performance Standards | GB265-88,,ASTM D445 |
Capillary Viscometer | Conform to SH/T0173-92 Technical Conditions of Glass Capillary Viscometer, Conform to JJG155 Verification Regulation of Routine Capillary Viscometer |
Method of Display | 7 inch color LCD |
Temperature Control Range | Room temperature-100℃ |
decision procedure: | Fiber optic sensor determination, automatic calculation |
Cleaning method | Automatic cleaning, automatic drying |
Testing Range | Kinematic Viscosity:0.6~17000mm2/s |
Temperature Control Accuracy | ±0.1℃ |
Timing Accuracy | ±0.1S |
Timing Range | 0.0S-999.9S |
Printer | Thermal printer, high-speed and lower consumption, with 55 millimeter-wide printing paper |
Temperature Testing Components | Precise imported platinum electric resistance |
Heating power | 800W |
Sample Installing Quantities | 2pieces |
Working Environment | Temperature: 0℃~40℃ Relative Humidity: <80% |
Power Supply | AC220V±10% 50Hz |
Dimension(largest) | 360*370*520(L*W*H) |
Weight | 20Kg |
Technical parameters
Methods: GB/T265
Measuring range: 0.6-17000mm2/s
Temp range: room temp +5℃ ~ 100.0℃;
Temperature control accuracy: ±0.1℃;
Timing range: 0.0s ~ 999h999s;
Timing accuracy: 60min not more than ±0.01%;
Sample Quantity: 2 sets of capillary viscometers (indicate viscosity range when ordering);
Use environment: Ambient temperature 10℃ ~ 35℃, relative humidity ≤ 85%;
Temperature sensor: PT100 platinum resistance;
Storage: 1000 sets of historical data can be stored for easy query;
Result output: at the same time can be equipped with U disk output function, output to the PC for long-term storage
Output format: The output format of the result USB flash disk is CSV or EXCEL.
Packing list
S/N | Name | Quantity | Unit | Remarks |
1 | Full-automatic viscosity tester | 1 | set | |
2 | Special viscosity tube | 4 | piece | |
3 |
Sample injector
|
1 | piece | |
4 | Printing paper | 2 | piece | |
5 | Electric aspirator | 1 | set | |
6 | certificate | 1 | copy | |
7 | instructions | 1 | copy | |