제품 세부 정보

Created with Pixso. Created with Pixso. 상품 Created with Pixso.
윤활유 시험 장비
Created with Pixso.

Determination Of Trace Nitrogen In Liquid Petroleum Hydrocarbons SH708 Chemiluminescence Method

Determination Of Trace Nitrogen In Liquid Petroleum Hydrocarbons SH708 Chemiluminescence Method

브랜드 이름: Shengtai Instrument
모델 번호: Sh708
모크: 1
지불 조건: 티/티
공급 능력: 10000sets/년
자세한 정보
원래 장소:
중국
인증:
ASTM D4629
온도 조절 범위:
실온 ~ 1050 50
온도 조종 정확도:
± 3 ℃
가스 소스 요구 사항:
고순도 아르곤 : 99.995% 이상의 순도
고순도 산소:
99.995% 순도 이상
전원:
AC220V ± 22V, 50Hz ± 0.5Hz, 1500W
치수:
숙주 : 305 (w) × 460 (d) × 440 (h) mm
온도 조절:
40
무게:
호스트 : 20kg
포장 세부 사항:
나무 케이스
강조하다:

Chemiluminescence nitrogen analyzer for petroleum

,

Trace nitrogen testing equipment for hydrocarbons

,

SH708 lubricating oil nitrogen detector

제품 설명

SH708 Chemiluminescence Nitrogen Analyzer
The SH708 chemiluminescence nitrogen analyzer adopts the chemiluminescence method to determine total nitrogen content. It enhances resistance to impurity interference, eliminates unstable factors caused by the titration cell locking operation in the coulometric method, and significantly improves the instrument sensitivity.
Key system components are imported to ensure reliable performance of the entire unit.
The analyzer is suitable for the determination of total nitrogen content in petroleum products, chemical raw materials and finished products, including paraffin oil, diesel fuel, gasoline, fuel oil, lubricating oil, liquefied petroleum gas (LPG) and natural gas.
It complies with the following standards:
SH/T 0657: Determination of trace nitrogen in liquid petroleum hydrocarbons (Oxidative combustion and chemiluminescence method)
ASTM D4629
GB/T 17674: Determination of nitrogen content in crude oil (Boat injection chemiluminescence method)
Chemiluminescence Method Trace Nitrogen Content Analyzer in accordance with ASTM D4629 and ASTM D5762
Ultraviolet Fluorescence Sulfur & Nitrogen-in-Oil Analyzer
Ultraviolet Fluorescence Total Sulfur & Nitrogen-in-Oil Analyzer for Light Hydrocarbons, ASTM D5453
ASTM D5453 Ultraviolet Fluorescence Sulfur & Nitrogen-in-Oil Analyzer
The performance characteristics of
1, the use of pneumatic support instrument cover, open the instrument cover internal structure at a glance.
2. The front shape and repeatability of low and small content are better.
3, the instrument can be continuously switched on for 24 hours continuous use of accurate chemiluminescence nitrogen determination instrument.
4. The total nitrogen content in the sample was rapidly measured by chemiluminescence method.
5. High-precision data acquisition and the application of computer technology provide a reliable guarantee for data acquisition, control and processing.
Technical parameters:
Basic parameters: Sample type: liquid, solid and gas
Determination method: chemiluminescence method
Sample injection volume: solid sample: 1-20mg
Liquid Sample: 5-20μl
Gas sample: 1-5ml
Measuring range: 0.1 ~ 10000mg/L
 
certainty of measurement:

Concentration value(ppm)Sample volume(μL)RSD(%)
0.12025
51010
50105
100103
5000103

 
Determination Of Trace Nitrogen In Liquid Petroleum Hydrocarbons SH708 Chemiluminescence Method 0
Temperature control range: room temperature ~ 1050℃
Temperature control accuracy: ±3℃
Gas source requirements: high purity argon: purity above 99.995%
High purity oxygen: above 99.995% purity
Power source: AC220V±22V, 50Hz±0.5Hz, 1500W
Dimensions: Host: 305(W)×460(D)×440(H)mm
Temperature control: 550 (W) x 460 x 440 mm (H) (D)
Weight: host: 20kg
Temperature control: 40 ℃
Complete set of equipment requirements: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operating software, etc.
Other options: computer, solid sampler, gas sampler.

Temperature control range

room temperature ~ 1050℃
 

Temperature control accuracy

±3℃
 

Gas source requirements

high purity argon: purity above 99.995%
 

High purity oxygenabove 99.995% purity
Power source

AC220V±22V, 50Hz±0.5Hz, 1500W
 

DimensionsHost: 305(W)×460(D)×440(H)mm
Temperature control550 (W) x 460 x 440 mm (H) (D)
Weight: host20kg
Temperature control40 ℃
Complete set of equipment requirementshost (data acquisition, control system),

 
Packing list

S/NName Unit Quantity Remarks
1Hostset1 
2Samplerset1 
3Quartz tubepiece1Installation and carrying
4Standard samplebox4 
5Quartz elbowpiece1 
6Membrane dryerpiece1Imported from Japan
7Communication cablepiece1 
8power cordpiece2 
9Power line of cracking furnacepiece1 
10Polytetrafluoroethylene pipemeter8Φ3
11Silica gel tubecentimeter20Φ3
12Silica gel tubecentimeter20Φ5
13Large clippiece1 
14Warranty card certificatecopy1 
15Instructioncopy1 
16Half moon ceramic ringpiece4 
17Sampling probepiece210ul
18Fusepiece22A
19Air pressure cappiece4 
20Thermocouplepiece1S-type platinum rhodium platinum
21Injection padpiece50 
22Computerset1Self-prepared