| ブランド名: | Shengtai Instrument |
| モデル番号: | SH708 |
| Moq: | 1 |
| 支払い条件: | T/T |
| 供給能力: | 10000セット/年 |
SH708 Chemiluminescence Nitrogen Analyzer
The SH708 chemiluminescence nitrogen analyzer adopts the chemiluminescence method to determine total nitrogen content. It enhances resistance to impurity interference, eliminates unstable factors caused by the titration cell locking operation in the coulometric method, and significantly improves the instrument sensitivity.
Key system components are imported to ensure reliable performance of the entire unit.
The analyzer is suitable for the determination of total nitrogen content in petroleum products, chemical raw materials and finished products, including paraffin oil, diesel fuel, gasoline, fuel oil, lubricating oil, liquefied petroleum gas (LPG) and natural gas.
It complies with the following standards:
SH/T 0657: Determination of trace nitrogen in liquid petroleum hydrocarbons (Oxidative combustion and chemiluminescence method)
ASTM D4629
GB/T 17674: Determination of nitrogen content in crude oil (Boat injection chemiluminescence method)
Chemiluminescence Method Trace Nitrogen Content Analyzer in accordance with ASTM D4629 and ASTM D5762
Ultraviolet Fluorescence Sulfur & Nitrogen-in-Oil Analyzer
Ultraviolet Fluorescence Total Sulfur & Nitrogen-in-Oil Analyzer for Light Hydrocarbons, ASTM D5453
ASTM D5453 Ultraviolet Fluorescence Sulfur & Nitrogen-in-Oil Analyzer
The performance characteristics of
1, the use of pneumatic support instrument cover, open the instrument cover internal structure at a glance.
2. The front shape and repeatability of low and small content are better.
3, the instrument can be continuously switched on for 24 hours continuous use of accurate chemiluminescence nitrogen determination instrument.
4. The total nitrogen content in the sample was rapidly measured by chemiluminescence method.
5. High-precision data acquisition and the application of computer technology provide a reliable guarantee for data acquisition, control and processing.
Technical parameters:
Basic parameters: Sample type: liquid, solid and gas
Determination method: chemiluminescence method
Sample injection volume: solid sample: 1-20mg
Liquid Sample: 5-20μl
Gas sample: 1-5ml
Measuring range: 0.1 ~ 10000mg/L
certainty of measurement:
| Concentration value(ppm) | Sample volume(μL) | RSD(%) |
| 0.1 | 20 | 25 |
| 5 | 10 | 10 |
| 50 | 10 | 5 |
| 100 | 10 | 3 |
| 5000 | 10 | 3 |
![]()
Temperature control range: room temperature ~ 1050℃
Temperature control accuracy: ±3℃
Gas source requirements: high purity argon: purity above 99.995%
High purity oxygen: above 99.995% purity
Power source: AC220V±22V, 50Hz±0.5Hz, 1500W
Dimensions: Host: 305(W)×460(D)×440(H)mm
Temperature control: 550 (W) x 460 x 440 mm (H) (D)
Weight: host: 20kg
Temperature control: 40 ℃
Complete set of equipment requirements: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operating software, etc.
Other options: computer, solid sampler, gas sampler.
| Temperature control range | room temperature ~ 1050℃ |
| Temperature control accuracy | ±3℃ |
| Gas source requirements | high purity argon: purity above 99.995% |
| High purity oxygen | above 99.995% purity |
| Power source | AC220V±22V, 50Hz±0.5Hz, 1500W |
| Dimensions | Host: 305(W)×460(D)×440(H)mm |
| Temperature control | 550 (W) x 460 x 440 mm (H) (D) |
| Weight: host | 20kg |
| Temperature control | 40 ℃ |
| Complete set of equipment requirements | host (data acquisition, control system), |
Packing list
| S/N | Name | Unit | Quantity | Remarks |
| 1 | Host | set | 1 | |
| 2 | Sampler | set | 1 | |
| 3 | Quartz tube | piece | 1 | Installation and carrying |
| 4 | Standard sample | box | 4 | |
| 5 | Quartz elbow | piece | 1 | |
| 6 | Membrane dryer | piece | 1 | Imported from Japan |
| 7 | Communication cable | piece | 1 | |
| 8 | power cord | piece | 2 | |
| 9 | Power line of cracking furnace | piece | 1 | |
| 10 | Polytetrafluoroethylene pipe | meter | 8 | Φ3 |
| 11 | Silica gel tube | centimeter | 20 | Φ3 |
| 12 | Silica gel tube | centimeter | 20 | Φ5 |
| 13 | Large clip | piece | 1 | |
| 14 | Warranty card certificate | copy | 1 | |
| 15 | Instruction | copy | 1 | |
| 16 | Half moon ceramic ring | piece | 4 | |
| 17 | Sampling probe | piece | 2 | 10ul |
| 18 | Fuse | piece | 2 | 2A |
| 19 | Air pressure cap | piece | 4 | |
| 20 | Thermocouple | piece | 1 | S-type platinum rhodium platinum |
| 21 | Injection pad | piece | 50 | |
| 22 | Computer | set | 1 | Self-prepared |