Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

Nombre De La Marca: Shengtai Instrument
Número De Modelo: SH124
Moq: 1
Términos De Pago: T/T
Capacidad De Suministro: 100000s/año
Información Detallada
Lugar de origen:
Porcelana
Estándar ejecutivo:
DL/T421, GB/T5654
Rango de prueba:
2,0 x 105 ~ 1,0 x 1013 Ω M.
Tiempo de la temperatura constante:
0 ~ 59 minutos
Tiempo de carga:
0 ~ 99 segundos
Tiempo de alta:
0 ~ 9 minutos
Rango de control de temperatura:
15 ~ 100℃, exactitud ±0.5℃ del control de la temperatura
Tipo de electrodo:
Tres electrodo terminal, control de doble temperatura del electrodo interno y externo
Material de electrodo:
acero especial
Material de aislamiento:
Ptfe
Espaciamiento del electrodo:
2.0 mm
Capacitancia vacía de la taza:
30.0pF
Resistencia a aislamiento de vidrio vacío:
> 3.0 x 1012 Ω
Fuente de energía:
CA 220V± el 10%, 50Hz± el 5%
Fuerza:
500 w o menos
Ambiente de trabajo:
Temperatura 10 ~ 35 ℃, humedad ≤ 85%
Detalles de empaquetado:
caja de madera
Resaltar:

automatic transformer oil dielectric loss tester

,

transformer oil volume resistivity test equipment

,

SH124 oil testing equipment with warranty

Descripción del Producto

 

SH124 automatic volume resistivity tester is designed and manufactured according to the requirements of the People's Republic of China power industry standard DL/T421-2009 and the national standard GB/T5654. It is used for measuring the volume resistivity of liquid media such as insulating oil and fuel oil.

SH124 automatic volume resistivity measuring instrument adopts MCS-51 series MCU as the system control core, color LCD display, Chinese man-machine dialogue, guide operation, the measurement process is fully automated (automatic cup change, automatic shift), and rolling storage of 200 test data;

And combined with modern new technology developed from.

The whole equipment of advanced design, reasonable structure, simple operation, safe and reliable, is the contemporary technology level of same sort products at home and abroad the highest performance index, the most perfect resistivity tester, particularly useful in the application of oil monitoring, power sector test results accord with national standard DL421-91 the insulating oil volume resistivity measurement.

Automatic Tan Delta Tester for Transformer Oil, Volume Resistivity Meter

Automatic Volume Resistivity Tester for fire resistant Oil

Automatic Cleaning Volume Resistivity Tester

Automatic Insulating Oil Volume Resistivity Tester

Technical parameters

Executive standard: DL/T421, GB/T5654

Test range: 2.0 x 105 ~ 1.0 x 1013 Ω m.

Test accuracy: repeatability:

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

Reproducibility:

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

Test voltage: 500 VDC maximum error 0.5 %

Constant temperature time: 0 ~ 59 minutes

Charging time: 0 ~ 99 seconds

Discharge time: 0 ~ 9 minutes

Temperature control range: 15 ~ 100℃, temperature control accuracy ±0.5℃

Electrode cup parameters:

Electrode type: three terminal electrode, internal and external electrode double temperature control

Electrode material: special steel

Insulation material: PTFE

Electrode spacing: 2.0mm

Empty cup capacitance: 30.0pF

Empty glass insulation resistance: > 3.0 x 1012 Ω

Power source: AC 220V± 10%, 50Hz± 5%

Power: 500 w or less

Working environment: temperature 10 ~ 35℃, humidity ≤ 85%

 

SH124 Automatic volume resistivity tester

 

 

Executive standard DL/T421, GB/T5654
Test range 2.0 x 105 ~ 1.0 x 1013 Ω m.
Test accuracy: repeatability

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

Reproducibility  

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

 

Test voltage: 500 VDC maximum error 0.5 %

 

Constant temperature time

0 ~ 59 minutes

 

Charging time 0 ~ 99 seconds
Discharge time 0 ~ 9 minutes
Temperature control range 15 ~ 100℃, temperature control accuracy ±0.5℃
Electrode type three terminal electrode, internal and external electrode double temperature control
Electrode material

special steel

 

Insulation material PTFE
Electrode spacing 2.0mm
Empty cup capacitance 30.0pF
Empty glass insulation resistance > 3.0 x 1012 Ω
Power source AC 220V± 10%, 50Hz± 5%
Power 500 w or less
Working environment temperature 10 ~ 35℃, humidity ≤ 85%

Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 0

Packing list

S/N Name Quantity Unit Remarks
1 Host 1 set  
2 Electrode cup 1 set  
3 power cord 1 piece  
4 Instructions 1 copy  
5 Packing list 1 copy  
6 Certificate warranty card 1 copy