detail produk

Created with Pixso. Beranda Created with Pixso. Produk Created with Pixso.
Peralatan pengujian minyak
Created with Pixso.

SH708 Chemiluminescence Nitrogen Analyzer | High Sensitivity | ASTM D4629 | Fast & Stable for Oil & Gas Testing

SH708 Chemiluminescence Nitrogen Analyzer | High Sensitivity | ASTM D4629 | Fast & Stable for Oil & Gas Testing

Nama Merek: Shengtai Instrument
Nomor Model: SH708
Moq: 1
Ketentuan Pembayaran: T/T
Kemampuan pasokan: 5000set/tahun
Informasi Rinci
Tempat asal:
Cina
Rentang kendali suhu:
Suhu kamar ~ 1050 ℃
Akurasi kontrol suhu:
± 3 ℃
Persyaratan sumber gas:
Argon Kemurnian Tinggi: Kemurnian di atas 99.995%
Oksigen kemurnian tinggi:
di atas 99,995% kemurnian
Sumber Daya:
AC220V±22V, 50Hz±0,5Hz
Kontrol Suhu:
40 ℃
Kemasan rincian:
Karton
Menyoroti:

Chemiluminescence Nitrogen Analyzer high sensitivity

,

Nitrogen Analyzer for oil gas testing

,

SH708 Analyzer ASTM D4629 compliant

Deskripsi produk

PRODUCT DESCRIPTION

SH708 chemiluminescence nitrogen determination instrument using chemiluminescence method to determine the total nitrogen content, improve the ability of anti-impurity interference, avoid the electric quantity method of titration cell lock operation and thus bring unstable factors, so that the sensitivity of the instrument is greatly improved.

The key components of the system are imported, which ensures the performance of the whole machine reliably.

Is suitable for the determination of paraffin oil, diesel oil, petrol, fuel oil, lubricating oil, liquefied petroleum gas and natural gas, and other oil products, chemical raw materials and finished product of the total nitrogen content, implement standard SH/T 0657 trace nitrogen in liquid petroleum hydrocarbons assay (oxidation burning and chemiluminescence method, ASTM D4629, GB/T 17674 the determination of nitrogen content in the crude oil boat injection chemiluminescence method.

Chemiluminescence Method Trace Nitrogen Content Analyzer as Per ASTM D4629 and ASTM D5762

 

The performance characteristics of

 

1, the use of pneumatic support instrument cover, open the instrument cover internal structure at a glance.

2. The front shape and repeatability of low and small content are better.

3, the instrument can be continuously switched on for 24 hours continuous use of accurate chemiluminescence nitrogen determination instrument.

4. The total nitrogen content in the sample was rapidly measured by chemiluminescence method.

5. High-precision data acquisition and the application of computer technology provide a reliable guarantee for data acquisition, control and processing.

 

Technical parameters:

 

Basic parameters: Sample type: liquid, solid and gas

Determination method: chemiluminescence method

Sample injection volume: solid sample: 1-20mg

Liquid Sample: 5-20μl

Gas sample: 1-5ml

Measuring range: 0.1 ~ 10000mg/L

 

measurement accuracy:

Concentration value (ppm)

Injection volume(μL)

RSD()

0.1

20

25

5

10

10

50

10

5

100

10

3

5000

10

3

 

 

 

 


Temperature control range: room temperature ~ 1050℃

Temperature control accuracy: ±3℃

Gas source requirements: high purity argon: purity above 99.995%

High purity oxygen: above 99.995% purity

Power source: AC220V±22V, 50Hz±0.5Hz, 1500W

Dimensions: Host: 305(W)×460(D)×440(H)mm

Temperature control: 550 (W) x 460 x 440 mm (H) (D)

Weight: host: 20kg

Temperature control: 40 ℃

Complete set of equipment requirements: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operating software, etc.

Other options: computer, solid sampler, gas sampler.

SH708 Chemiluminescence Nitrogen Analyzer | High Sensitivity | ASTM D4629 | Fast & Stable for Oil & Gas Testing 0 

 

Temperature control range

room temperature ~ 1050℃

 

Temperature control accuracy

±3℃

 

Gas source requirements

high purity argon: purity above 99.995%

 

High purity oxygen

above 99.995% purity

Power source

AC220V±22V, 50Hz±0.5Hz, 1500W

 

Dimensions

Host: 305(W)×460(D)×440(H)mm

Temperature control

550 (W) x 460 x 440 mm (H) (D)

Weight: host

20kg

Temperature control

40 ℃

Complete set of equipment requirements

host (data acquisition, control system),

 

Packing list

 

S/N

Name

Unit

Quantity

Remarks

1

Host

set

1

 

2

Sampler

set

1

 

3

Quartz tube

piece

1

Installation and carrying

4

Standard sample

box

4

 

5

Quartz elbow

piece

1

 

6

Membrane dryer

piece

1

Imported from Japan

7

Communication cable

piece

1

 

8

power cord

piece

2

 

9

Power line of cracking furnace

piece

1

 

10

Polytetrafluoroethylene pipe

meter

8

Φ3

11

Silica gel tube

centimeter

20

Φ3

12

Silica gel tube

centimeter

20

Φ5

13

Large clip

piece

1

 

14

Warranty card certificate

copy

1

 

15

Instruction

copy

1

 

16

Half moon ceramic ring

piece

4

 

17

Sampling probe

piece

2

10ul

18

Fuse

piece

2

2A

19

Air pressure cap

piece

4

 

20

Thermocouple

piece

1

S-type platinum rhodium platinum

21

Injection pad

piece

50

 

22

Computer

set

1

Self-prepared
 

 

Contact us

Shandong Shengtai Instrument Co.,ltd

ADD:6-8 time base NO.15 lanxiang road tianqiao Area Jinan city

TEL:+86 0531-85919987 85929987

FAX:+86 0531-85957987

Whatsapp:+86 13370527859

Email:13370527859wang@labtool.net

Web:www.labtool.net/en