Détails des produits

Created with Pixso. Accueil Created with Pixso. Produits Created with Pixso.
Équipement d'essai d'huile de lubrification
Created with Pixso.

ASTM D93 Automatic Flash Point Meter with 7-inch Touch Screen, 2ml-10ml Sample Size, and ±0.1℃ Temp Control Accuracy

ASTM D93 Automatic Flash Point Meter with 7-inch Touch Screen, 2ml-10ml Sample Size, and ±0.1℃ Temp Control Accuracy

Nom De La Marque: Shandong Shengtai Instrument Co., Ltd.
Numéro De Modèle: SH105E
MOQ: 1
Conditions De Paiement: T/T
Capacité D'offre: 10000 ensembles/an
Des informations détaillées
Lieu d'origine:
Chine
Certification:
GB/T 5208 GB/T 5207 GB7634 GB/T 21790 GB/T 261 GB/T 14454.1 ISO 3679 ASTM D93
Mode d'affichage:
Écran couleur tactile de 7 pouces
Gamme de détection de point d'inflammabilité:
TA ~ 300℃ ou -30 ~ +80℃
Échantillon:
2 ml ~ 10 ml
Précision du contrôle de la température:
± 0,1°C
Tension d'alimentation:
AC220V ± 10% 50Hz
Puissance entière:
ne dépassant pas 300W
Détails d'emballage:
caisse en bois
Mettre en évidence:

ASTM D93 flash point meter

,

automatic closed flash point tester

,

lube oil flash point analyzer

Description du produit
ASTM D93 Automatic Essence Rapid Equilibrium Closed Flash Point Meter Sample 2ml - 10ml
SH105E Full Automatic Essence Closed Flash Point Meter

The SH105E full-automatic essence closed flash point tester is designed and manufactured in accordance with the requirements of standards GB/T 261, GB/T 14454.1 essence flash point, and GB/T 5208 Determination of Flash Point Rapid Balance Closed Cup Method. This instrument also meets the requirements of ISO 3679 standard.

This instrument features advanced electronic temperature control with appropriate interface circuits to achieve automated temperature control. It includes functions such as automatic switching of heating power and automatic temperature control. The instrument is simple to operate, structurally reasonable, accurate in detection, stable in performance, and intuitive in display. It serves as an ideal substitute for imported instruments and meets the requirements of petroleum, chemical industry, coating, paint, essence, spice commodity inspection, and scientific research institutions for fast closed flash point testing of petroleum products.

This instrument is particularly suitable for testing the closed cup flash point of various paints, coatings, adhesives, solvents, petroleum and related products within the range of room temperature to +300℃ or -30℃ to 100℃.

Main Technical Indicators and Parameters
  • Standard micro printer with automatic measurement and thermal printing
Display Mode 7-inch touch color screen display
Flash Point Detection Range RT to 300℃ or -30 to +80℃
Sample Size 2ml to 10ml
Measurement Precision Difference between two experimental results is less than 2℃ (same operator); Less than 3℃ (different operators)
Temperature Control Accuracy ± 0.1℃
Ignition Device Electronic ignition point
Opening Method Automatic opening
Cooling Method Semiconductor internal cooling and external compressor cooling cycle
Data Storage Can store 200 sets of historical data
Compliant Standards Compliant with Chinese standards
Power Supply Voltage AC220V ± 10% 50Hz
Whole Power Not exceeding 300W
Environmental Temperature 5℃ to 30℃
Relative Humidity 30 to 80%
Size 370 × 280 × 380mm
Weight 15KG
Circulating Bath Size 450 × 480 × 580mm
Weight 28kg (optional)
ASTM D93 Automatic Flash Point Meter with 7-inch Touch Screen, 2ml-10ml Sample Size, and ±0.1℃ Temp Control Accuracy 0
Note: The appearance pictures, dimensions, volume, and weight of the instrument are for reference only. If there are any updates to the instrument, there may be slight changes without prior notice.
Packing List
S/N Name Quantity Unit Remarks
1 Automatic closed flash point meter 1 Set
2 Oil cup 1 Piece
3 AC power cord 1 Piece
4 Printing paper 1 Roll
5 Instruction manual 1 Piece
6 Packing list 1 Copy
7 Certificate 1 Copy
Quality Assurance

Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:

  • The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity
  • The materials and main components provided meet the technical requirements specified in the technical documentation
  • The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts)
  • We are responsible for free maintenance of any instrument quality issues that occur during the warranty period
  • Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees
  • Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine
  • After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee
ASTM D93 Automatic Flash Point Meter with 7-inch Touch Screen, 2ml-10ml Sample Size, and ±0.1℃ Temp Control Accuracy 1